HPCL tank dip chart

Updated 2 November 2026

Short answer

HPCL tank charts are plain horizontal cylinders with flat ends. Four common models are 9 KL and 16 KL (200 cm across), 22 KL (227 cm across) and 35 KL (266 cm across). Worked out from diameter and length, the litres match HP's printed charts within 2.5 litres.

The models

Model Inside diameter Length Deadwood Full Source
9 KL 200 cm 300 cm – 9,425 L HP calibration chart, 9 KL
16 KL 200 cm 550 cm – 17,279 L HP calibration chart, 16 KL
22 KL 227 cm 600 cm – 24,282 L HP calibration chart, 22 KL
35 KL 266 cm 660.7 cm – 36,716 L HP calibration chart, 35 KL; length fitted to its figures

Sizes that are not round numbers

HPCL’s sizes, 16, 22 and 35 KL, differ from BPCL’s and IOCL’s. The full litres are slightly more than the name: a 16 KL tank holds about 17,279 litres to the top. The size in the name is a round figure; the chart goes all the way to the top of the tank.

Litres every 10 cm

Litres at each dip, rounded to the litre. For a dip between rows, use the dip to litres calculator, which works to the millimetre.

Dip 9 KL · 200 16 KL · 200 22 KL · 227 35 KL · 266
10 cm 176 323 376 449
20 cm 491 899 1,049 1,256
30 cm 886 1,625 1,900 2,279
40 cm 1,342 2,460 2,883 3,466
50 cm 1,843 3,378 3,968 4,783
60 cm 2,378 4,360 5,134 6,206
70 cm 2,940 5,390 6,365 7,715
80 cm 3,520 6,454 7,646 9,296
90 cm 4,113 7,541 8,964 10,935
100 cm 4,712 8,639 10,307 12,619
110 cm 5,311 9,738 11,665 14,336
120 cm 5,904 10,825 13,026 16,077
130 cm 6,485 11,889 14,381 17,831
140 cm 7,047 12,919 15,717 19,588
150 cm 7,582 13,901 17,025 21,338
160 cm 8,083 14,819 18,293 23,070
170 cm 8,538 15,654 19,506 24,776
180 cm 8,934 16,380 20,650 26,443
190 cm 9,249 16,956 21,707 28,060
200 cm 9,425 17,279 22,653 29,614
210 cm 23,457 31,091
220 cm 24,061 32,474
230 cm 33,742
240 cm 34,868
250 cm 35,813
260 cm 36,506
270 cm

How these figures are made

Each model is a horizontal cylinder with flat ends, worked out from its inside diameter and length. The formula is exact for a perfect cylinder. These are the same figures the Dip Density app shows. This site and the app are independent and not made by Hindustan Petroleum or any oil company.

Figures here are for reference. Your oil company’s certified calibration chart, approved instruments and the Marketing Discipline Guidelines always prevail.

Questions

Can I use this chart instead of my tank's certified chart?

No. Your tank's own calibration chart, certified for that tank, always prevails. Use these figures to check a reading or when the chart is not at hand.

Why do my chart's figures differ by a litre or two?

Printed charts round each figure, and some were drawn up from measured tanks. The cylinder formula is exact for the stated diameter and length. Differences of one or two litres are rounding.

My model is not here.

Send its chart from the Dip Density app. We add the model, and it appears in the app for everyone.

Read next